<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"><channel><title>Signal Field Guide</title><description>Practical field notes, schematics, and calculators for industrial I/O, instrumentation, and sensor troubleshooting.</description><link>https://signalfieldguide.com/</link><language>en-us</language><item><title>4–20 mA vs 0–10 V: the practical difference</title><link>https://signalfieldguide.com/guide/4-20ma-vs-0-10v/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/4-20ma-vs-0-10v/</guid><description>They can represent the same pressure, level, or temperature. The useful difference is what each signal lets you notice when the wiring stops behaving.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>SIGNAL BASICS</category></item><item><title>PNP vs NPN sensors without the guessing</title><link>https://signalfieldguide.com/guide/pnp-vs-npn-sensors/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/pnp-vs-npn-sensors/</guid><description>The labels sound abstract until you look at where the output current goes. Start there, then match the sensor to the PLC input arrangement.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>WIRING</category></item><item><title>Why does a 4–20 mA loop read 0 mA?</title><link>https://signalfieldguide.com/guide/why-4-20ma-reads-zero/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/why-4-20ma-reads-zero/</guid><description>A zero reading is not a diagnosis. It is an invitation to separate the supply, the path, the transmitter, and the meter position.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>TROUBLESHOOTING</category></item><item><title>The PLC shows the wrong analog value</title><link>https://signalfieldguide.com/guide/plc-analog-input-wrong-value/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/plc-analog-input-wrong-value/</guid><description>When the number is stable but wrong, the signal may be innocent. Scaling and input mode are the first places to look.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>TROUBLESHOOTING</category></item><item><title>M12 connector pinouts: A-coded, D-coded, and the traps</title><link>https://signalfieldguide.com/guide/m12-connector-pinout/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/m12-connector-pinout/</guid><description>M12 describes a connector family, not one universal pinout. The key is to identify the coding and application before you trust the pin numbers.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>CONNECTORS</category></item><item><title>RTD vs thermocouple: what changes at the input</title><link>https://signalfieldguide.com/guide/rtd-vs-thermocouple/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/rtd-vs-thermocouple/</guid><description>Both can report temperature, but they ask the input card to do different kinds of measurement and compensation.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>SENSORS</category></item><item><title>What sensor shielding actually does</title><link>https://signalfieldguide.com/guide/shielding-analog-signals/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/shielding-analog-signals/</guid><description>Noise has a route. Learn how cable routing, drain wires, and reference points change what the analog input sees.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>SIGNAL QUALITY</category></item><item><title>Loop power, explained without the hand-waving</title><link>https://signalfieldguide.com/guide/loop-power-explained/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/loop-power-explained/</guid><description>The supply, the transmitter, and the load all share one loop. Here is what each one is allowed to consume.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>SIGNAL BASICS</category></item><item><title>A PNP sensor stays ON</title><link>https://signalfieldguide.com/guide/pnp-sensor-stays-on/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/pnp-sensor-stays-on/</guid><description>A permanently active output can be a short, a reference problem, or a target that never leaves the sensor&apos;s switching zone.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>TROUBLESHOOTING</category></item><item><title>An M12 sensor drops out</title><link>https://signalfieldguide.com/guide/intermittent-m12-sensor/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/intermittent-m12-sensor/</guid><description>Intermittent faults become less mysterious when you make the connector, cable, and movement part of the test.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>TROUBLESHOOTING</category></item><item><title>The analog value wanders</title><link>https://signalfieldguide.com/guide/analog-signal-noise/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/analog-signal-noise/</guid><description>A wandering number is a pattern, not a verdict. Find out whether the noise arrives with a machine state, a cable route, or a reference point.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>TROUBLESHOOTING</category></item><item><title>IO-Link vs. discrete sensors: what diagnostics change</title><link>https://signalfieldguide.com/guide/io-link-vs-discrete-sensors-what-diagnostics-change/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/io-link-vs-discrete-sensors-what-diagnostics-change/</guid><description>A switching sensor answers one control question; an IO-Link device can also describe its condition, measurements, and configuration. The difference matters most when technicians need to separate a process fault from a setup or replacement-device fault.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>IO-LINK</category></item><item><title>RS-485 termination: why Modbus works on the bench and fails in the plant</title><link>https://signalfieldguide.com/guide/rs-485-termination-why-modbus-works-on-the-bench-and-fails-in-the-plant/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/rs-485-termination-why-modbus-works-on-the-bench-and-fails-in-the-plant/</guid><description>A bench-proven Modbus RTU link may fail when real cable length, topology, electrical interference, and grounding arrangements expose its RS-485 physical layer. Diagnose the bus before blaming registers or PLC logic.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>NETWORKS</category></item><item><title>24 V DC voltage drop: a field calculation that prevents ghost faults</title><link>https://signalfieldguide.com/guide/24-v-dc-voltage-drop-field-calculation-prevents-ghost-faults/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/24-v-dc-voltage-drop-field-calculation-prevents-ghost-faults/</guid><description>A 24 V DC supply can be correctly set at the cabinet while a device receives too little voltage when the machine works. A simple loop calculation and a loaded measurement at the device separate wiring loss from elusive control faults.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>POWER &amp; WIRING</category></item><item><title>Inductive proximity sensors: target material, sensing distance, and hysteresis</title><link>https://signalfieldguide.com/guide/inductive-proximity-sensors-target-material-sensing-distance-hysteresis/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/inductive-proximity-sensors-target-material-sensing-distance-hysteresis/</guid><description>Inductive proximity sensors are dependable only when their target, mounting, and switching margins suit the actual machine. Understanding the sensing field makes weak or unstable detection easier to prevent and diagnose.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>SENSORS</category></item><item><title>PLC raw counts to engineering units: a scaling check that catches bad values</title><link>https://signalfieldguide.com/guide/plc-raw-counts-to-engineering-units-scaling-check/</link><guid isPermaLink="true">https://signalfieldguide.com/guide/plc-raw-counts-to-engineering-units-scaling-check/</guid><description>Scaling faults can mimic a failed transmitter, a bad process condition, or a PLC programming error. Reading the raw count alongside the configured range makes the fault visible before it becomes a maintenance guess.</description><pubDate>Sat, 12 Sep 2026 00:00:00 GMT</pubDate><category>PLC ANALOG</category></item></channel></rss>